When your installation uses conduit — steel, PVC, flexible, or corrugated — the point where that conduit enters an enclosure matters. A standard cable gland grips the cable. A conduit cable gland grips the conduit. That distinction drives IP rating, mechanical integrity, and compliance. Getting it wrong costs you both.

At Difvan, we manufacture and supply a complete range of conduit cable glands — barrier type, compression type, and flexible conduit variants — in brass, stainless steel, and nylon. Whether your system uses 20mm steel conduit in an industrial panel, PVC conduit on a commercial build, or flexible metallic conduit on a machine, we have the right fitting.

We supply directly to panel builders, electrical contractors, distributors, and project procurement teams worldwide. If you need certified, consistently manufactured conduit cable glands in volume — with documentation and reliable lead times — you are in the right place.

Conduit cable gland in brass and stainless steel for steel and PVC conduit entry IP65 rated industrial fitting

Is This Page for You?

If any of the following applies to your project or business, read on:

  • A panel builder sourcing conduit cable glands for steel or PVC conduit entries into industrial enclosures
  • An electrical contractor specifying conduit fittings that achieve IP65 at the enclosure entry — not just at the conduit run
  • A procurement manager consolidating supply of barrier and compression conduit glands across a project bill of materials
  • A distributor building stock of standard conduit gland sizes for the construction, industrial, or commercial electrical market
  • A design engineer specifying the correct conduit-to-enclosure transition for a 20mm or metric conduit system

If your requirement is for cable glands on unprotected cables — without any conduit system — our standard cable gland range is the right starting point. This page covers conduit-specific fittings only.

Our Conduit Cable Gland Range

Our conduit cable gland range covers every major conduit type used in industrial, commercial, and infrastructure installations worldwide. Every product is available in multiple materials and thread standards — metric, NPT, and PG — and supplied with CE marking and RoHS compliance documentation as standard.

Type

Conduit Compatibility

Thread Entry

Material

IP Rating

Size Range

Barrier Conduit Gland

Steel conduit, rigid conduit, metal conduit

Metric / NPT / PG

Brass / SS-316

IP65

M16 – M63 / 1/2″–2″ NPT

Compression Conduit Gland

PVC conduit, plastic conduit, rigid conduit

Metric / PG

Brass / Nylon

IP65

M16 – M50 / PG 9 – PG 29

Flexible Conduit Gland

Flexible metallic conduit (FMC), PVC flex conduit

Metric / PG

Brass / Nylon

IP54–IP65

15mm – 32mm ID

PVC Conduit Gland

PVC rigid and corrugated conduit

Metric

Brass / Nylon

IP65

16mm – 50mm conduit OD

20mm Conduit Gland

20mm steel or PVC conduit, standard knockout

Metric M20

Brass / Nylon / SS

IP65

20mm conduit OD

Conduit Hub (Locknut Type)

Steel conduit, EMT, IMC conduit

NPT thread

Zinc / Brass

IP54

1/2″–2″ NPT

Brass Gland for Plastic Conduit

PVC, nylon, corrugated plastic conduit

Metric / PG

Nickel Plated Brass

IP65

M16 – M40

 

All conduit cable glands are available in standard metric, NPT, and PG thread entries. Custom conduit OD fits, extended thread lengths, and special finishes are available for bulk and OEM orders. Contact us with your conduit specification and we will confirm the correct gland type and size.

Barrier vs Compression — Which Conduit Cable Gland Do You Need?

The most common specification question we receive is this: barrier type or compression type? The answer depends on your conduit material, thread availability, and IP requirement. Here is the full comparison:

Feature

Barrier Conduit Gland

Compression Conduit Gland

Primary Function

Seals conduit entry to enclosure — provides mechanical stop and IP seal at the conduit-to-enclosure joint

Compresses around conduit OD to grip and seal — suited for thin-wall and plastic conduit types

Conduit Type

Steel conduit, rigid metal conduit (RMC), EMT (with bushing), armoured conduit

PVC conduit, flexible plastic conduit, corrugated conduit, light steel conduit

Thread Connection

Threaded directly into enclosure knockout — same thread as conduit (metric, NPT, or PG)

Slides over conduit OD — compression nut grips and seals the conduit wall

Seal Method

Rubber seal inside gland body seats against the conduit end — forms watertight joint at entry point

Compression cone and clamping ring deform slightly around conduit OD — no thread required

IP Rating Achieved

IP65 standard; IP68 with double seal variant

IP54 to IP65 depending on conduit fit and seal quality

Material Options

Brass (standard), SS-316 (corrosive environments)

Brass for metal enclosures, Nylon/PA66 for plastic enclosures, SS-316 on request

Best Applications

Industrial panels, external conduit runs, metal enclosure entries, outdoor cable routes

Domestic and commercial panels, PVC conduit systems, lightweight cable management

Difvan Supply

Yes — full metric, NPT, PG range in brass and SS-316

Yes — metric and PG range in brass and nylon, bulk available

 

If you are specifying for a steel conduit system in an industrial facility, barrier conduit glands are almost always the correct choice. For PVC conduit on commercial or infrastructure projects, compression types are the standard. For flexible conduit — see the flexible conduit section below. If you are still unsure, send us your conduit type and enclosure spec and we will advise.

Conduit Type Compatibility Guide

Not all conduit cable glands fit all conduit types. Use this table as your compatibility reference — matching your conduit material and construction to the correct gland entry method and recommended product.

Conduit Type

Material

Entry Method

Recommended Gland

IP Achievable

Difvan Stock

Steel Rigid Conduit (RMC)

Galv. Steel

Threaded (NPT/Metric)

Barrier conduit gland — brass or SS-316

IP65

Yes

EMT (Thin-Wall)

Steel

Compression or locknut

Conduit hub locknut type — NPT or metric

IP54

Yes

IMC (Intermediate)

Steel

Threaded (NPT)

Barrier conduit gland — NPT thread

IP65

Yes

PVC Rigid Conduit

PVC Plastic

Compression or glued

Compression conduit gland — brass or nylon

IP65

Yes

Corrugated PVC Conduit

Flexible PVC

Compression — over OD

Flexible conduit gland — over corrugated OD

IP54

Yes

Flexible Metallic (FMC)

Steel/Aluminium

Connector + locknut

Flexible conduit gland — FMC compatible

IP54

Yes

Liquid-Tight Flex (LFMC)

PVC coated FMC

Compression connector

Liquid-tight flexible conduit gland

IP65

Yes

20mm Steel Conduit

Steel

M20 threaded knockout

20mm barrier conduit gland — brass or nylon M20

IP65

Yes

 

Note on 20mm conduit: The 20mm conduit entry (M20 thread) is by far the most common conduit gland size we supply. It covers standard 20mm steel conduit, 20mm PVC conduit, and the standard 20mm knockout used in the majority of European and Asian industrial enclosures. We hold this size in continuous production stock in both brass and nylon.

Cable Glands for Flexible Conduit — FMC, LFMC & PVC Flex

Flexible conduit presents a specific challenge at the enclosure entry point: you cannot use a threaded barrier gland on a conduit that has no thread. Our flexible conduit cable glands are designed specifically for this application.

Flexible Metallic Conduit (FMC) Glands

FMC is widely used for the final connection to motors, drives, and vibrating equipment — where rigidity is not practical. Our FMC conduit cable glands use an over-OD design: the gland body accepts the conduit end, and a compression nut and sealing cone grip the exterior of the conduit. Available in brass and SS-316, with IP54 to IP65 sealing depending on the conduit OD fit.

Liquid-Tight Flexible Conduit (LFMC) Glands

Liquid-tight flexible conduit — also known as Sealtite or LFMC — has a PVC jacket over the metallic core. Our LFMC cable glands compress around the smooth PVC outer jacket, providing a watertight seal at the conduit entry. Particularly specified for outdoor equipment connections, washdown environments, and anywhere the conduit run is exposed to moisture.

Corrugated PVC Flexible Conduit Glands

Corrugated plastic conduit (sometimes called split conduit or corrugated loom) is commonly used in cable management for machinery and instrumentation. Our cable glands for flexible PVC conduit grip the corrugated exterior profile directly — providing mechanical retention and a basic IP seal at the enclosure entry point.

For all flexible conduit applications, please specify your conduit type and outer diameter when enquiring. Flexible conduit ODs vary between manufacturers even for nominally the same size — we will confirm the correct gland variant for your specific conduit.

20mm M20 conduit cable gland and multiple sizes for metric NPT and PG conduit systems bulk supply

Conduit Cable Gland Size Chart — Metric, NPT & PG Thread

The size chart below covers our standard conduit cable gland range across all thread standards. The 20mm conduit cable gland (M20) and 1/2″ NPT are our highest-volume sizes — both held in continuous production stock. All other sizes are available on standard lead time.

 

Thread Size

Conduit OD Range (mm)

Gland Type

Material

IP Rating

Common Application

M16

12 – 15

Barrier / Comp.

Brass / Nylon

IP65

Light conduit, 16mm PVC, instrument cable

M20

16 – 19

Barrier / Comp.

Brass / Nylon

IP65

20mm steel & PVC conduit — most common knockout

M25

20 – 24

Barrier / Comp.

Brass / SS-316

IP65

25mm rigid steel conduit, medium cable routes

M32

27 – 31

Barrier

Brass / SS-316

IP65

32mm steel conduit, multi-core industrial cables

M40

35 – 39

Barrier

Brass / SS-316

IP65

40mm conduit, larger cable bundles

M50

44 – 48

Barrier

Brass / SS-316

IP65

50mm heavy steel conduit, power cables

M63

56 – 60

Barrier

SS-316

IP65

Large conduit entries, industrial power distribution

1/2″ NPT

21.3 OD

Barrier (Hub)

Brass / SS-316

IP65

North American 1/2″ steel conduit — standard knockout

3/4″ NPT

26.7 OD

Barrier (Hub)

Brass / SS-316

IP65

North American 3/4″ conduit

1″ NPT

33.4 OD

Barrier (Hub)

Brass / SS-316

IP65

North American 1″ rigid conduit

PG 11

16 – 18

Compression

Brass / Nylon

IP65

Light PVC conduit, 20mm PVC — European spec

PG 16

21 – 24

Compression

Brass / Nylon

IP65

25mm PVC conduit, standard European knockout

PG 21

27 – 30

Compression

Brass / Nylon

IP65

32mm PVC conduit, European industrial

PG 29

35 – 38

Compression

Brass / SS-316

IP65

40mm conduit — European industrial panels

Custom sizes, extended thread depths, and alternative conduit OD fits are available for project-specific and OEM orders. Please contact us with your conduit OD and enclosure wall thickness for a custom recommendation.

China Conduit Cable Gland

Conduit Hub vs Cable Gland — Understanding the Difference

This is one of the most searched questions in conduit cable management — and one of the most important to get right for IP compliance. Here is the full comparison:

 

Feature

Conduit Hub

Conduit Cable Gland

Primary Purpose

Terminates conduit into enclosure wall — mechanical connection only

Terminates conduit AND seals cable jacket — mechanical + IP protection

Seals the Cable?

No — conduit hub does not grip or seal the cable inside the conduit

Yes — internal seal grips cable jacket directly for full IP rating

IP Rating

IP54 in most cases — depends on conduit system seal integrity

IP65 standard, IP68 with double compression seal variant

Use With

Used where conduit system provides the ingress protection (sealed conduit runs)

Used where cable entry point must independently achieve IP rating

Thread Standard

Primarily NPT (US standard) — also available in metric

Metric, NPT, and PG thread — full range

Typical Region

North America — NEC conduit wiring method

Global — IEC, NEC, and mixed-standard installations

Difvan Supply

Yes — locknut conduit hub type in NPT and metric

Yes — full barrier and compression conduit gland range

Bottom line: if your installation requires a specific IP rating at the enclosure entry point — which most IP65-rated panels and outdoor enclosures do — a conduit cable gland is the correct specification. A conduit hub or plain conduit fitting will not independently achieve this. This is a common specification oversight that leads to failed IP testing and site rework.

Stainless Steel And Brass Conduit Cable Glands For Corrosion Resistant Outdoor And Marine Environments

Material Options — Brass, Stainless Steel & Nylon

Choosing the right material for your conduit cable gland ensures long-term performance and compliance with your enclosure’s material and environmental requirements.

Material

Key Properties

Best For

Brass (Nickel Plated)

High mechanical strength, good corrosion resistance, compatible with steel and PVC conduit, RoHS compliant

Standard industrial panels, steel conduit, PVC conduit, commercial installations

SS-316 Stainless Steel

Superior corrosion resistance, chloride-resistant (2% Mo), food-grade surface finish option

Outdoor conduit entries, coastal / offshore, food processing, chemical environments

Nylon (PA66)

Lightweight, non-conductive, chemical-resistant, no galvanic corrosion with plastic conduit

PVC conduit systems, plastic enclosures, light commercial, instrumentation panels

Brass cable gland for plastic conduit: Brass compression conduit glands are the most widely used fitting for PVC conduit entries into steel enclosures. The brass body provides mechanical durability at the enclosure wall while the compression seal accommodates the plastic conduit OD. If you are connecting PVC conduit to a plastic enclosure, a nylon conduit gland is preferred to avoid the galvanic compatibility issue between brass and certain plastic enclosure materials.

Industries & Applications — Where Conduit Cable Glands Are Specified

Conduit cable glands appear across virtually every industrial and commercial electrical installation. Here are the primary sectors and applications we supply into:

Industrial Panel Building

The single largest application for conduit cable glands. Panel builders use barrier and compression conduit glands to terminate steel and PVC conduit runs at enclosure entries. The M20 and M25 metric sizes are the standard for most European and Asian industrial panels.

 

Infrastructure & Civil Projects

Water treatment plants, pumping stations, substations, and infrastructure facilities use conduit wiring systems throughout. Conduit cable glands are the standard entry fitting wherever conduit meets a waterproof or dust-proof enclosure on these projects.

 

Commercial Construction — MEP Fit-Out

Mechanical, electrical, and plumbing (MEP) contractors on commercial builds specify conduit cable glands for electrical distribution boards, DB panels, and service enclosures. Compression conduit glands in nylon and brass for PVC conduit are the standard fitting in these environments.

 

Machine Building & OEM Equipment

Machine builders use flexible conduit — FMC and LFMC — to route cables to motors, actuators, and drives. Our flexible conduit cable glands are the correct termination fitting at the machine enclosure entry, providing both mechanical strain relief and IP sealing.

Utilities & Power Distribution

Transformer kiosks, cable pillars, ring main units, and secondary distribution equipment all use conduit cable gland entries. We supply panel builders and utilities equipment manufacturers with conduit glands for both cable and conduit entries on a project-by-project and framework basis.

Marine & Offshore — Conduit Systems

Offshore platforms and vessels that use conduit wiring systems specify SS-316 conduit cable glands for all topside and marine-environment conduit entries. Our SS-316 barrier conduit glands with IP65 sealing are the standard specification for these environments.

How to Specify the Right Conduit Cable Gland — Checklist

Before submitting an enquiry, confirm these parameters. The more detail you provide, the faster and more accurate our recommendation will be:

  1. Conduit type — steel rigid, EMT, PVC rigid, PVC corrugated, FMC, LFMC
  2. Conduit outer diameter (OD) — in mm or inches — not nominal size
  3. Thread standard — metric (M-thread), NPT (American), or PG (European)
  4. Thread size required — M20, M25, 1/2″ NPT, PG 16, etc.
  5. Gland type — barrier (threaded conduit end) or compression (over conduit OD)
  6. Enclosure wall thickness — relevant for thread engagement length
  7. IP rating required — IP54, IP65, or IP68
  8. Environment — indoor, outdoor, wet area, coastal/marine, washdown
  9. Material preference — brass, SS-316, nylon, or as specified
  10. Certifications required — CE, RoHS, specific project documentation
  11. Quantity required — for pricing, lead time, and stocking confirmation

Send us this information and we will respond with a specific product recommendation, datasheet, and project pricing within 24 hours.

DIFVAN FACTORY IMAGES

Frequently Asked Questions — Conduit Cable Glands

A conduit cable gland is designed to terminate a conduit run at an electrical enclosure entry point. Unlike a standard cable gland — which grips directly onto a cable’s outer jacket — a conduit cable gland interfaces with the conduit itself, providing a mechanical connection between the conduit and the enclosure while also sealing the cable entry against ingress. Depending on the type (barrier or compression), the gland may grip the conduit end or compress around the conduit outer diameter. The result is a complete, IP-rated conduit-to-enclosure transition — mechanical retention, cable protection, and IP seal in one fitting.
 
A barrier conduit gland uses a threaded body that screws into the enclosure knockout with the same thread as the conduit — the conduit end butts against an internal rubber seal inside the gland body, creating a watertight barrier at the conduit entry. This type is primarily used with rigid metal conduit (steel or stainless) and achieves IP65 or higher. A compression conduit gland works differently: it slides over the conduit outer diameter and a compression nut and cone are tightened to grip and seal around the conduit OD — no thread on the conduit is required. Compression types are preferred for plastic (PVC) conduit, corrugated conduit, and flexible conduit systems. Please refer to the comparison table on this page for a full breakdown.

In most cases, yes — a barrier conduit cable gland can replace a traditional conduit fitting at an enclosure entry, and in doing so it adds IP sealing at the cable entry point that a standard conduit fitting does not provide. The distinction is important: a conduit fitting (like an EMT connector) mechanically terminates the conduit but does not independently seal the cable inside. A conduit cable gland does both. If your installation requires an IP65-rated cable entry, a conduit cable gland is the correct component rather than a plain conduit fitting or hub.

A conduit hub (also called a Myers hub or insulated throat hub in North American terminology) is primarily a mechanical fitting that connects a rigid conduit to an enclosure wall. It provides a threaded, weatherproof mechanical joint — but it does not grip or independently seal the cable inside the conduit. A conduit cable gland adds cable-sealing functionality to this junction: it grips the cable jacket via an internal seal, so the IP rating at the entry point is maintained regardless of what happens further along the conduit run. For full IP65 at the enclosure entry, a conduit cable gland is the correct specification. Please see the comparison table on this page. 

Our conduit cable glands are available across the full standard thread range: Metric (M16, M20, M25, M32, M40, M50, M63), NPT (1/2″, 3/4″, 1″, 1-1/4″, 1-1/2″), and PG thread (PG 11, PG 16, PG 21, PG 29). The 20mm conduit cable gland (M20 thread) is our most commonly ordered size, covering the standard 20mm knockout in both steel and PVC conduit applications. Please refer to the size chart on this page or contact us for custom sizes.

Yes — a brass cable gland is fully compatible with PVC (plastic) conduit, and it is a common combination in industrial installations. When connecting a brass conduit gland to a PVC conduit, use a compression-type gland rather than a threaded barrier type, since most PVC conduit is not threaded. Our compression conduit glands in brass are specifically sized for standard PVC conduit outer diameters and provide a secure, IP65-rated seal at the conduit-to-enclosure entry point. For all-plastic installations or where galvanic compatibility is important, we also offer nylon conduit cable glands.

Our standard MOQ for conduit cable glands is 200 pieces per SKU for standard sizes in our established range. For custom configurations — specific conduit OD fits, extended thread lengths, or special materials — MOQ is typically 500 pieces. We support project-based purchasing with flexible scheduling and can supply mixed-SKU orders for conduit gland kits covering a full cable schedule. Contact us with your bill of materials and we will provide project-specific pricing and lead time.

Get In Touch

Contact Difvan Directly

Response within 24 hours. Factory direct — no middlemen.

Factory Address DIFVAN Co., Ltd.
No.1 HongQi Road, Xinguang Industrial Zone,
Liushi, Yueqing, Wenzhou, Zhejiang, China 325603

Why Panel Builders and Procurement Teams Choose Difvan for Conduit Cable Glands

Here is what sets our conduit cable gland supply apart from the alternatives your team may already be considering:

 

What We Offer

What This Means for Your Project

Direct Manufacturer

You buy from the factory — no distributor margin, no intermediary who does not understand the technical spec. Faster responses, better pricing, direct access to production.

Full Conduit Gland Range

Barrier, compression, and flexible conduit types — metric, NPT, and PG — in brass, SS-316, and nylon. One supplier covers your entire conduit cable gland bill of materials.

M20 Always in Stock

The 20mm conduit cable gland (M20 thread) is our highest-volume size and held in continuous production stock in brass and nylon. No waiting on lead time for your most common size.

CE & RoHS Documentation

Every order ships with CE declaration and RoHS compliance. No chasing documentation after delivery — it comes with the product as standard.

Brass for PVC Conduit — Ready

Our brass compression conduit glands for plastic conduit are a stock item. If you are specifying brass cable glands for PVC conduit entries, we can fulfil from stock.

Bulk & Project Supply

We support single-project purchasing, ongoing call-off orders, and framework supply agreements. Whatever your buying model, we can structure supply around it.

25+ Years Manufacturing

Our factory in Yueqing has produced industrial cable management components since 1997. Conduit cable glands are a core product line — not an afterthought.

Samples Before Bulk Order

We send samples before you commit to bulk. If the fit, finish, or performance is not right for your application, you find out before — not after — you have placed your order.

Request a Quote — Conduit Cable Glands

Whether you need 200 pieces of M20 brass barrier conduit glands for a panel project or a full range of compression conduit fittings for ongoing distribution — we can fulfil it. Send us your specification and we will return pricing and lead time within 24 hours.

Blog Post

Patch Panel Comparison: Cat5e vs. Cat6 – What’s the Real Difference?

When building or upgrading a network, choosing the right patch panel is a critical decision that affects both performance and scalability. Two common options are Cat5e and Cat6 patch panels. Though they look nearly identical at a glance, the internal structure and performance capabilities vary significantly. In this post, we at Difvan break down the

Read More »
Keystone patch panel compared with a punch-down patch panel

Keystone Patch Panel vs. Punch-Down Patch Panel: Which Is Better for Your Network?

In structured cabling systems, patch panels help you organize Ethernet cables, simplify network management, and maintain reliable connections. Two common options are the keystone patch panel and the punch-down patch panel. Your choice depends on your network configuration, budget, installation requirements, and future maintenance needs. When comparing a keystone patch panel vs punch-down design, the

Read More »
Colour-coded patch cords connected to labelled patch panels

Patch Panel Labeling Guide: Best Practices + Free Template

If you are managing a network rack, clear patch panel labels help you identify connections without tracing cables manually. A simple rack-panel-port naming system gives every connection a unique identifier you can use on the panel, remote outlet, cable schedule, and maintenance records. You can also define your labeling requirements when working with a patch

Read More »
Scroll to Top